Vapor Cooled Current Leads

 

 

 

 

 

 

 

Click the image above to view the Current Lead 
brochure in Adobe Acrobat

(document size is 1747 KB).

 

 

AMI vapor cooled current leads are the industry standard for introducing high currents into the liquid helium dewar environment. State-of-the-art techniques provide the most efficient way to transfer high currents from 300K to 4.2K. Standard and custom designs from 25 amperes to 75,000 amperes have been built and used.

The heat capacity of helium vapor is used in these counterflow leads to minimize the liquid helium consumption for a specified operating current. Leads of this type have been shown to evaporate 2.8 x 10-3 liters per hour per ampere for each lead pair when operated at the design current (40% less at zero current). AMI leads are expected to provide this performance under normal conditions, however a more conservative value of 3.2 x 10-3 liters per hour per ampere is recommended for system design calculations. A voltage drop of less than 0.2 volts per lead pair at the rated current is typical. A pressure difference of approximately 2 mm of mercury (0.03 psi) is developed through the leads at the rated current.

Break-away vapor cooled current leads are available and represent a popular configuration for persistent magnet operation. Break-away leads are supplied in two sections so that the upper section can be detached from the lower section during persistent magnet operation. Helium consumption is significantly reduced because current lead thermal paths are eliminated. Automatic lead retractors can be incorporated for automation and control of the break-away lead configuration.

AMI can provide custom vapor cooled current leads for many combinations of current ratings, sizes, lengths, and mounting configurations. An AMI Technical Sales Representative is available to help you define your current lead requirements. Available features include:

High Current Designs                       • Brass Conductors                        • High Voltage Isolation            

Specialty Clusters                            • Flexible Leads                              • Off-gas Collection Fittings

Hybrid Gas Cooled HTS Leads       • Retractable Leads and Wands      • Superconducting Bus Bars

Model Number
Amperes
Consumed He, liters/(hr-pair)
Type (see fig.)
L-50
50
0.16

A
L-75
75
0.24

A
L-100
100
0.32

A
L-150
150
0.48

A
L-200
200
0.64

A
L-250
250
0.80

A
L-500
500
1.6

A
L-1000
1,000
3.2

B
L-2000
2,000
6.4

B
L-3000
3,000
9.6

B
L-5000
5,000
16.0

B
L-10000
10,000
32.0

B
A 1/4 1/4 1/4 1/4 3/8 3/8 1/2 1/2 1/2 1/2 3/4 3/4
B 1-1/2 1-1/2 1-1/2 1-1/2 2 2 3 3 3 3-3/4 4-1/2 7
C 1 1 1 1 1-1/4 1-1/4 1-1/2 2 2-1/2 3 3 3-1/2
D 1 1 1-1/2 1-1/2 2
E 9/32 9/32 9/32 9/32 9/32 9/32 9/16 9/32 7/16 7/16 7/16 7/16
F 3/8 3/8 3/8 3/8 1/2 1/2 3/4 3/4 3/4 1 1 1 & 3
G 3/8 3/8 3/8 3/8 1/2 1/2 1/2 7/8 1-1/8 1-1/4 1-1/2 2-1/2
H 1/4 1/4 1/4 1/4 3/8 3/8 1/2 1/2 3/4 1 1 1-3/4
I 2-1/4 2-1/2 2-5/8 3 3-3/4
J 1-3/4 2 2-1/8 2-1/4 3-1/4
K 1/4 NPT 1/4 NPT 1/4 NPT 1/4 NPT 3/8 NPT 3/8 NPT 1/2 NPT 1 1-1/4 1-3/8 1-5/8 --
L 7/8 7/8 7/8 7/8 1 1 1-3/16 5/8 5/8 5/8 5/8 3/8
M 9/16 9/16 9/16 9/16 9/16 9/16 3/4 3/8 3/8 3/8 3/8 --
N 9/32 9/32 9/32 9/32 9/32
O 1/4 1/4 1/4 1/4 3/8 3/8 1/2 3/4 1 1-1/8 1-3/8 2-1/8
R 0.201 0.201 0.201 9/32 13/32 17/32 17/32 3/8
S 1 1 1 1 1 1 1 1-1/2 1-1/2 1-1/2 1-1/2 4
T 1/16 1/16 1/16 1/16 1/8 1/8 1/8 1/4 1/4 1/4 1/4 3/8
U 1/4 1/4 1/4 1/2 1/2 1/2 1/2 1&2-1/2
V 16-5/8 16-5/8 16-5/8 16-5/8 16-5/8 16-5/8 17-1/2 19-1/2 19-1/2 19-1/2 19-1/2 24
W Adj. Adj. Adj. Adj. Adj. Adj. Adj. 1-1/2 2 2 2 4
X 1/4 1/4 1/4 1/4 3/8 3/8 1/2 3/4 1 1-1/8 1-3/8 2-1/8
All dimensions in inches and are subject to change


Rev. 5 Manual in Adobe Acrobat 4.0 format (340 KB)


Back to Superconducting Magnet Systems page

AMI HomePage | Sales | Superconducting Magnets | Liquid Level Instrumentation
Technical Support | Customer Services | AMI Picturebook | E-Mail AMI